Discover our range of Vacuum pumps, air compressors and other general lab apparatus. Vacuum pumps are used for a number of applications prescribed by some international standards. For example, explore our De-Airing water systems required for triaxial soil testing machines (ASTM, BS, EN, NF) that assess soil permeability as well as specific gravity and density of bituminous mixtures (ATM D2041). Discover our range of compressors essential when testing procedures require good air quality, longevity and efficiency.
Vacuum Pumps, Air Compressors and Various
Air Compressors
Both models are ideal for laboratory use.
86-D2015
Description
Both models are ideal for laboratory use. The 86-D2015/A model is particularly suited for use with the DYNATRIAX Dynamic triaxial system.
Products
86-D2015
Laboratory air compressor. 8 BAR max constant pressure. 230V/50Hz/1Ph
86-D2015/A
Air compressor 10 bar maximum pressure (8 bar continuos working pressure) 4Kw, power, 33,4 mc/hour air flow, 200lt tank capacity. 400V/50Hz/3Ph
86-D2015/Z
Laboratory air compressor. 8 BAR max constant pressure. 110V/60Hz/1PH
78-PV0250/7
Laboratory air compressor. 220-240V/50Hz/1Ph
86-D2018
Laboratory air compressor, 14 bar max. pressure. 230V/50Hz/1Ph.
86-D2015/Y
Laboratory air compressor, 10 bar max. pressure, 8 bar for continuous use. 50 liters capacity. 220 V, 60 Hz, 1 ph
Technical Specifications
Models | 86-D2015 | 86-D2015/Y 86-D2015/Z | 86-D2015/A 86-D2015/AZ |
Max. Pressure | 10 bar | 9 bar | 10 bar |
Max. Pressure (continuous use) | 8 bar | 8 bar | 8 bar |
Tank capacity | 50 liters | 50 liters | 200 liters |
Air flow | 14 m3/h | 33,4 m3/h | |
Power | 1.5 kW | 4 kW | |
Overall dimensions (mm) | 850x355x675(h) | 1600x520x1050(h) | |
Weight approx.: | 44 kg | 125 kg | |
Mould dimensions* | 320 x 260 x 195 mm | ||
Roller vibration | Yes, adjustable frequency from 10 to 50 Hz (optional) | ||
Heated foot | Yes (optional) | ||
Heated base | Yes (optional) | ||
Electrical supply | 380 V, 50 Hz, 3 ph, or | ||
Power rating | 3000 W |
*To produce slabs down to 38 mm thickness. Maximum slab thickness varies with bitumen mixes composition.
Accessories and Spare Parts
86-D2064
Rubber tube dia 6.5 x 16.5 mm 2 m long, for vacuumpumps
86-D2019
Air treatment unit comprehending: air dryer, particle filter 5M, oil filters 1M, coalescence filter 0.01M. 230V/50-60Hz/1Ph
86-D2060
Rubber tube dia 5 x 13 mm 2 m long
86-D2062
Rubber tube dia 8 x 12 mm 6 m long
86-D2070
Rubber stoppers set
28-WF2016/2
Water Trap for Air/Water assembly
86-D2019/Z
Air treatment unit comprehending: air dryer, particle filter 5M, oil filters 1M, coalescence filter 0.01M. 110V/60Hz/1Ph
Air Drying Unit
Can be installed between the vacuum pump (see Vacuum pumps) and the apparatus to be de-aired
86-D0819 and 86-D2005
Description
Can be installed between the vacuum pump (see Vacuum pumps) and the apparatus to be de-aired (e.g. Pyknometers). It has to be filled with a suitable Dessicant (e.g. Silica gel dessicant 86-D0819). This unit is used to avoid /limit the water vapour to mix with the oil of the vacuum pump, which may cause, as specified, serious damage to the pump when in notable concentration. For more details about complete de-airing systems and the various applications see Additional information.
Specifications
- Plastic frame with acrylic cylinder
- Dessicant capacity: 500 g approx.
- Overall dimensions: 185×300(h) mm approx.
- Weight approx.: 1 kg (empty)
Main Features
- The PReSBOX produces a prismatic specimen with nominal dimensions of 450 mm (lenght) x 150 mm (width) x 120 to 185 mm (height)
- Asphalt prisms prepared in the PReSBOX compactor can be sawn or cored to produce 4-6 prismatic beams or 1-4 cylindrical specimens
- The PReSBOX can be operated by a single person Produces specimens with excellent air void distribtion and particle orientation
- Designed for an easy unlocking of the compaction mould, facilitating an effortless speciment extraction at safe height, handling and user safety
Products
86-D2005
Air drying unit. For use with Silica gel with indicator, 86-D0819
Technical Specifications
Buyer’s Guide
The following table summarize the most common tests in which are required De-airing systems and Vacuum apparatus. These recommendations are our interpretation to perform efficiently the test. If in doubt we are at your disposal to give you all necessary information.
Standard Test/Determination
1) ASTM, BS, EN, NF De-airing water system for triaxial tests
2) —- Falling head permeability (Cell 38-T0185/1)
3) EN 12697-4 Recovery of binder by the fractionating column method
4) EN 12697-3 Binder recovery by rotary evaporation
5) EN 12697-1 Binder recovery by vacuum pump method
BS 598:102
6) ASTM D2041 Specific gravity and density of bituminous mixtures
Code | Description | Test 1) | Test 2) | Test 3) | Test 4) | Test 5) | Test 6) |
86-D2001 | Vacuum Pump | X | X |
|
| X |
|
86-D2003 | Vacuum pump |
|
| X | X |
| X |
86-D2004/5 | Vacuum gauge |
|
| X |
| X |
|
86-D2064 | Rubber tubes | X (2) | X (2) | X (2) | X (2) | X (2) | X (2) |
86-D2005 | Air drying unit | X | X |
|
|
| X |
86-D0819 | Silica gel | X (2) | X (2) |
|
|
| X (2) |
86-2004/1D | Vacuum regulator |
|
|
| X |
|
|
Accessories and Spare Parts
86-D0819
Silica gel with indicator. 1000 g
Electric Generator
For site use with electrically operated core drilling machines and other apparatus when mains curren
Electric Generator
Description
For site use with electrically operated core drilling machines and other apparatus when mains current is not available. It has a petrol driven engine.
It features a digital control panel with automatically adjusts the output voltage, two 16A-250V shuko sockets and one 12V charger.
Its sturdy construction and fully covering hull that reduces noise and protects the unit from dust and shocks makes this generator ideal for site use and mobile laboratories.
Products
86-D2250
Portable electric generator, 5kVA, 230V, 50H, 1ph.Petrol driven engine.
Technical Specifications
- AC Generator 50 Hz, synchronous, single-phase, 6.5 kVA, 230 V
- Manual recoil starting system
- Engine: 13 HP (7.1 kWm) – 393 cm3
- Fuel tank capacity: 25 l
- Sound power level: 85 dB(A)/7m
- Dimensions (lxwxh): 690 x 500 x 550 mm
- Weight approx.: 75 kg
Rubber tubes and stoppers
Rubber tubes and stoppers
Standards EN 12697-33 ASTM D8079
86-D2064, D2062, D2060
Description
Rubber tubes and stoppers
Products
86-D2060
Rubber tube dia 5 x 13 mm 2 m long
86-D2062
Rubber tube dia 8 x 12 mm 6 m long
86-D2070
Rubber stoppers set
Vacuum Pumps
Portable vacuum pumps, free air displacement 75 l/min, ultimate vacuum 0.1 and 0.01 mba
Standards ASTM D7981
86-D2001, 86-D2003
Description
Vacuum pumps are used for a number of applications concerning, above all, De-Airing systems of water. Water vapour sucked by the vacuum pump and mixed with the oil, producing emulsion, may cause serious damage to the pump when in notable concentration. For this reason it is important, for such applications, to propose a suitable de-airing system as the Air drying unit 86-D2005 filled with the Silica gel (dessicator salt) 86-D0819 (see \#air-drying-unit\#). Vacuum pumps can also be fit with a Vacuum gauge with pin regulating valve and bleed valve as our model 86-D2004/5 (see accessories) unless a similar gauge is not fit to the equipment to be connected as for example Large size pyknometer 75-D1122. For more detail about the de-airing systems see Additional information.
We propose two Vacuum pump models:
- 86-D2001 and 86-D2001/Z (110 V), for ultimate vacuum of 0.1 mbar
- 86-D2003 and 86-D2003/Z (110 V), for ultimate vacuum of 0.01 mbar
Products
86-D2001
Portable vacuum pump, free air displacement 75 l/min, ultimate vacuum 0.1 mbar. 230V/50-60Hz/1Ph
86-D2003
Two stage portable vacuum pump , ultimate vacuum 0,01 mbar, free air displacement 75 l/min. 230V/50-60Hz/1ph
86-D2003/Z
Two stage portable vacuum pump , ultimate vacuum 0,01 mbar, free air displacement 75 l/min. 110V/60Hz/1ph
86-D2001/Z
Portable vacuum pump, free air displacement 75 l/min, ultimate vacuum 0.1 mbar. 110 V, 60 Hz, 1 ph
Technical Specifications
Models 86- | D2001 D2001/Z | D2003 D2003/Z |
Free air displacement liter/min: | 75 | 75 |
Ultimate vacuum mbar: | 0.1 | 0.01 |
Power | 180 W | 240 W |
Dimensions approx.: | 335x155x280 mm | 335x155x280 mm |
Weight approx.: | 12,5 kg | 12,5 kg |
Accessories and Spare Parts
86-D2064
Rubber tube dia 6.5 x 16.5 mm 2 m long, for vacuum pumps
86-D2001/1
Special oil for vacuum pump 500 cc
86-D2004/5
Vacuum gauge 0 to -100kPa complete with connections for rubber hoses and bleed/ regulation pin valve
Vacuum Regulator
The vacuum fine regulation and monitoring are required by particular tests as for example the Binder
Standards ASTM D8079
86-D2004_D
Description
The vacuum fine regulation and monitoring are required by particular tests as for example the Binder recovery by rotary evaporation conforming to EN 12697-3 (see \#rotary-evaporator–for-binder-recovery\#). This unit satisfy this requirement. For more details concerning the most common applications, see the Buyers guide in the Additional information.
The metal case house the high precision vacuum regulator valve and the digital display unit.
- Range of regulation: 0 to 760 mm/hg
- Resolution of digital display: 0.001 bar
- Overall dimensions: 250x250x280 (h) mm
- Weight approx.: 7 kg
Products
86-D2004/1D
Vacuum regulator complete with digital display unit, 0,001 bar resolution. 110-230V/50-60Hz/1ph
86-D2004/1DZ
Vacuum regulator complete with gital display unit,0,001 bar resolution. 110V60Hz/1ph
Technical Specifications
Buyer’s Guide
The following table summarize the most common tests in which are required De-airing systems and Vacuum apparatus. These recommendations are our interpretation to perform efficiently the test. If in doubt we are at your disposal to give you all necessary information.
Standard Test/Determination
1) ASTM, BS, EN, NF De-airing water system for triaxial tests
2) —- Falling head permeability (Cell 38-T0185/1)
3) EN 12697-4 Recovery of binder by the fractionating column method
4) EN 12697-3 Binder recovery by rotary evaporation
5) EN 12697-1 Binder recovery by vacuum pump method
BS 598:102
6) ASTM D2041 Specific gravity and density of bituminous mixtures
Code | Description | Test 1) | Test 2) | Test 3) | Test 4) | Test 5) | Test 6) |
86-D2001 | Vacuum Pump | X | X |
|
| X |
|
86-D2003 | Vacuum pump |
|
| X | X |
| X |
86-D2004/5 | Vacuum gauge |
|
| X |
| X |
|
86-D2064 | Rubber tubes | X (2) | X (2) | X (2) | X (2) | X (2) | X (2) |
86-D2005 | Air drying unit | X | X |
|
|
| X |
86-D0819 | Silica gel | X (2) | X (2) |
|
|
| X (2) |
86-2004/1D | Vacuum regulator |
|
|
| X |
|
|